System Info & Network Status

CS121 Hardware
Specific information about the hardware model of the adapter.
CS121 Firmware
Detailed information about which firmware version is running on the adapter.
UPS Manufacturer
Manufacturers name of the UPS connected to the adapter usually matching the firmware.
UPS Model
Name of the UPS model that is selected by the user in the configuration.
Location
User defined information set in the configuration.
System Name
User defined information set in the configuration.
System Contact
User defined information set in the configuration.
Attached Devices
User defined information set in the configuration.
System Time
Time and date of the adapters clock.
Uptime
Indicates how long the adapter has been running since its last reboot.
Total Uptime
Amount of total operation time the adapter has been running since installation or firmware update.
System Information Help about 'System Information' 
CS121 HardwareCS121-C-2003
CS121 FirmwareCS121-SNMP v 3.93.30 100215

HyNetOS Rel. 2.4.1.41(pduc) - Jan 25, 2010
I*Target Server Rel. 2.4.1.26(pduc) - Oct 13, 2009
DRIVER Generex CS121.B Rel. 2.4.1.11(pduc) - Jul 25, 2008
Loader: BOOTMWT2-2(GNX), ROM-Version: 2.3.0(ak) - May 04, 2006
UPS ManufacturerPowertronix
UPS ModelQUASAR 3-1 SQ protocol
Location
System NameCS-121
System Contact
Attached DevicesUPS protected devices
System Time08.02.2012 02:42:25
Uptime9 days 7 hours 23 minutes 57 seconds
Total UptimeApprox. 777 days 17.7 hours

MAC Address
Registered Media Access Control number.
Network Speed
Ethernet communication speed of the CS121 adapter.
IP Address
Default IP address that will assigned to the adapter unless DHCP is active.
Subnet Mask
Defines the scope of local network segment for reducing network traffic.
Default Gateway
Address of the machine in local network segment for reaching other networks.
EMail Server
Hostname or IP address of the mail server.
Time Server
IP address of the server that the CS121 uses for setting its clock.
Telnet Server
Indicates whether the CS121 telnet server is running or not.
HTTP Server
Indicates whether the CS121 web server is running or not.
Obviously it is. :)
Upsmon Server
Indicates whether the CS121 UPSMON server is running or not.

When this option is enabled, the adapters information can be shown using UPSMON, and will show up in the list of Upsman servers when UPSMON does a server scan.
Use RCCMD2 Traps
Indicates whether the CS121 supports RCCMD traps or not.
This is necessary to use the RCCMD trap event job.
SNMP Server
Indicates whether the CS121 SNMP agent feature is activated or not.
Use SNMP Coldboot Trap
Indicates whether the CS121 sends a SNMP coldboot trap on startup or not.
Use SNMP Authentication Trap
Indicates whether the CS121 sends a SNMP authentication trap on SNMP access violations or not.
Modbus Server
Indicates whether the CS121 modbus over IP feature is activated or not.
DNS Server
IP address of the used DNS server.
Network Status Help about '' 
MAC Address00-02-0A-0A-0A-0A
Network SpeedAUTO
IP Address192.168.72.179
Subnet Mask255.255.255.0
Default Gateway192.168.72.253
DNS Server192.168.72.3
EMail Serversmtp.fastwebnet.it
Time Server192.168.72.3
Telnet ServerOn
HTTP ServerOn
Upsmon ServerOn
Use RCCMD2 TrapsYes
SNMP ServerOff
Use SNMP Coldboot TrapNo
Use SNMP Authentication TrapNo
Modbus ServerOn